Quad Tendon Autograft ACL Reconstruction

Quadriceps tendon grafts offer unique benefits for cruciate ligament reconstruction, such as a predictably large diameter, low morbidity,1 and a preferable stiffness profile for knee ligament reconstruction.

The QuadPro™ tendon harvester is designed to harvest a quadriceps or patellar tendon graft using a minimally invasive technique.2-4 The sharp tip cores out an approximate cylindrical graft. The harvester's ergonomically designed handle features graduations on the clear shaft to allow visualization of approximate graft length during harvesting. Available in four sizes (8 mm to 11 mm), the QuadPro tendon harvester can accommodate each patient’s unique needs as well as the surgeon’s preference for graft diameter.

The FiberTag® TightRope® implant facilitates attachment of single-ended grafts, such as quadriceps tendon grafts, to the ACL TightRope RT and ABS implants. FiberTag suture is integrated into the TightRope implant for a strong, consistent connection between the suture and TightRope loop. A simplified suturing technique, along with innovative packaging and the GraftClamp graft preparation instrument, make preparing quadriceps tendon grafts faster and more reproducible than ever.

References

1. Arthrex, Inc. LA1-00100-EN_K. Naples, FL; 2021.

2. Xerogeanes JW, Mitchell PM, Karasev PA, Kolesov IA, Romine SE. Anatomic and morphological evaluation of the quadriceps tendon using 3-dimensional magnetic resonance imaging reconstruction: applications for anterior cruciate ligament autograft choice and procurement. Am J Sports Med. 2013;41(10):2392-2399. doi:10.1177/0363546513496626

3. Hadjicostas PT, Soucacos PN, Berger I, Koleganova N, Paessler HH. Comparative analysis of the morphologic structure of quadriceps and patellar tendon: a descriptive laboratory study. Arthroscopy. 2007;23(7):744-750. doi:10.1016/j.arthro.2007.01.032

4. Krebs N, Yaish A, O’Neill N. Anatomic evaluation of the quadriceps tendon in cadaveric specimens: application for anterior cruciate ligament reconstruction graft choice. SMRJ. 2019;4(1):7961. doi:10.51894/001c.7961

View More

Quadriceps tendon grafts offer unique benefits for cruciate ligament reconstruction, such as a predictably large diameter, low morbidity,1 and a preferable stiffness profile for knee ligament reconstruction.

The QuadPro™ tendon harvester is designed to harvest a quadriceps or patellar tendon graft using a minimally invasive technique.2-4 The sharp tip cores out an approximate cylindrical graft. The harvester's ergonomically designed handle features graduations on the clear shaft to allow visualization of approximate graft length during harvesting. Available in four sizes (8 mm to 11 mm), the QuadPro tendon harvester can accommodate each patient’s unique needs as well as the surgeon’s preference for graft diameter.

The FiberTag® TightRope® implant facilitates attachment of single-ended grafts, such as quadriceps tendon grafts, to the ACL TightRope RT and ABS implants. FiberTag suture is integrated into the TightRope implant for a strong, consistent connection between the suture and TightRope loop. A simplified suturing technique, along with innovative packaging and the GraftClamp graft preparation instrument, make preparing quadriceps tendon grafts faster and more reproducible than ever.

References

1. Arthrex, Inc. LA1-00100-EN_K. Naples, FL; 2021.

2. Xerogeanes JW, Mitchell PM, Karasev PA, Kolesov IA, Romine SE. Anatomic and morphological evaluation of the quadriceps tendon using 3-dimensional magnetic resonance imaging reconstruction: applications for anterior cruciate ligament autograft choice and procurement. Am J Sports Med. 2013;41(10):2392-2399. doi:10.1177/0363546513496626

3. Hadjicostas PT, Soucacos PN, Berger I, Koleganova N, Paessler HH. Comparative analysis of the morphologic structure of quadriceps and patellar tendon: a descriptive laboratory study. Arthroscopy. 2007;23(7):744-750. doi:10.1016/j.arthro.2007.01.032

4. Krebs N, Yaish A, O’Neill N. Anatomic evaluation of the quadriceps tendon in cadaveric specimens: application for anterior cruciate ligament reconstruction graft choice. SMRJ. 2019;4(1):7961. doi:10.51894/001c.7961

View More

Educational Resources and Products

QuadPro™ Tendon Harvester Graft Harvesting System

Surgical Technique Animations | 04:19 | English | 03/03/2022 | AN1-000082-en-US C

QuadLink™ ACL Reconstruction Using the QuadPro™ Harvester and FiberTag® TightRope® Implants

John W. Xerogeanes, MD
Surgical Technique Videos | 23:44 | English | 11/18/2022 | VID1-002245-en-US B
QuadPro™ Tendon Harvester Surgical Technique
QuadPro™ Tendon Harvester Surgical Technique
Surgical Technique Guides | English | 02/10/2022 | LT1-000052-en-US D
FiberTag® TightRope® II Graft Preparation
FiberTag® TightRope® II Graft Preparation
Surgical Technique Animations | 03:50 | English | 03/03/2023 | AN1-000009-en-US C
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® Implant and FlipCutter® III Drill
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® Implant and FlipCutter® III Drill
Jason M. Scopp, MD
Case Presentation Videos | 02:54 | English | 09/09/2020 | VID1-000872-en-US C
QuadLink™ Graft Preparation Using the FiberTag® TightRope® II Implant
QuadLink™ Graft Preparation Using the FiberTag® TightRope® II Implant
Surgical Technique Guides | English | 08/25/2023 | LT1-000281-en-US A
Videos
(32)
arrow_drop_down
Videos
Documents
(17)
arrow_drop_down
Documents
English
(49)
arrow_drop_down
Languages

Surgical Technique Videos (11)

Minimally Invasive Quad Tendon Graft Harvest From a Proximal Approach Using the QuadPro™ Harvester
Minimally Invasive Quad Tendon Graft Harvest From a Proximal Approach Using the QuadPro™ Harvester
Trey Remaley, DO
13:22 | English | 04/15/2024 | VID1-006036-en-US A
QuadLink™ ACL Reconstruction With LET Using Knee FiberTak® FiberStaple™ Technique
QuadLink™ ACL Reconstruction With LET Using Knee FiberTak® FiberStaple™ Technique
Harris Slone, MD
14:33 | English | 08/18/2023 | VID1-004026-en-US A
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® II Implants and InternalBrace™ Technique
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® II Implants and InternalBrace™ Technique
Walter R. Lowe, MD
10:31 | English | 08/18/2023 | VID1-003951-en-US A
QuadLink™ ACL Reconstruction With a Lateral Extra-articular Tenodesis Using Knee FiberTak® Anchors
QuadLink™ ACL Reconstruction With a Lateral Extra-articular Tenodesis Using Knee FiberTak® Anchors
John W. Xerogeanes, MD
20:24 | English | 08/15/2023 | VID1-004027-en-US A
All-Inside, All-Epiphyseal QuadLink™ ACLR: FiberTag® TightRope® II Implant and Pediatric Guides
All-Inside, All-Epiphyseal QuadLink™ ACLR: FiberTag® TightRope® II Implant and Pediatric Guides
Paul Saluan, MD
27:40 | English | 05/15/2023 | VID1-003807-en-US A
QuadLink™ ACL Reconstruction Using the QuadPro™ Harvester and FiberTag® TightRope® Implants
QuadLink™ ACL Reconstruction Using the QuadPro™ Harvester and FiberTag® TightRope® Implants
John W. Xerogeanes, MD
23:44 | English | 11/18/2022 | VID1-002245-en-US B
Minimally Invasive Bone Quad Tendon ACL Reconstruction Using the QuadPro™ Harvester
Minimally Invasive Bone Quad Tendon ACL Reconstruction Using the QuadPro™ Harvester
Jason M. Scopp, MD
13:30 | English | 08/27/2021 | VID1-001766-en-US A
Quad Tendon Graft Preparation Using the FiberTag® TightRope® Implant
Quad Tendon Graft Preparation Using the FiberTag® TightRope® Implant
John W. Xerogeanes, MD
06:38 | English | 11/26/2019 | VID1-000368-en-US B
Minimally Invasive Quadriceps Tendon Harvest for ACL Reconstruction
Minimally Invasive Quadriceps Tendon Harvest for ACL Reconstruction
John W. Xerogeanes, MD
Surgical Technique Videos | 07:50 | English | 10/05/2018 | VID1-01274-EN A
Minimally Invasive Bone Quad Tendon (BQT) Graft Harvest for All-Inside ACL Reconstruction
Minimally Invasive Bone Quad Tendon (BQT) Graft Harvest for All-Inside ACL Reconstruction
Jason M. Scopp, MD
Surgical Technique Videos | 20:24 | English | 03/14/2018 | VID1-01276-EN A
SpeedWhip™ Rip-Stop Tendon Stitch using #2 FiberLoop® with FiberTag™
SpeedWhip™ Rip-Stop Tendon Stitch using #2 FiberLoop® with FiberTag™
Surgical Technique Videos | 01:51 | English | 03/02/2015 | VID1-00287-EN A

Surgical Technique Animations (3)

FiberTag® TightRope® II Graft Preparation
FiberTag® TightRope® II Graft Preparation
03:50 | English | 03/03/2023 | AN1-000009-en-US C
QuadPro™ Tendon Harvester Graft Harvesting System
QuadPro™ Tendon Harvester Graft Harvesting System
04:19 | English | 03/03/2022 | AN1-000082-en-US C

Surgical Technique Guides (6)


Brochures (7)

FiberTag® TightRope® II Implant
FiberTag® TightRope® II Implant
English | 02/08/2024 | DOC1-001275-en-US A
Knee Arthroscopy New Product & Technique Highlights
Knee Arthroscopy New Product & Technique Highlights
English | 03/29/2023 | evBR1-002467-en-US C
QuadPro™ Tendon Harvester
QuadPro™ Tendon Harvester
English | 01/31/2022 | LI1-000127-en-US C
QuadPro™ Tendon Harvester
QuadPro™ Tendon Harvester
English | 08/17/2021 | DOC1-000528-en-US A
GraftPro® Graft Preparation System
GraftPro® Graft Preparation System
English | 08/20/2020 | LB1-00043-EN D
TightRope® Attachable Button System
TightRope® Attachable Button System
English | 08/29/2018 | LB1-00056-EN C

Case Presentation Videos (6)

Quad Tendon ACL Reconstruction and Lateral Meniscus Root Repair Using the SutureLoc™ Implant
Quad Tendon ACL Reconstruction and Lateral Meniscus Root Repair Using the SutureLoc™ Implant
Rachel M. Frank, MD
10:49 | English | 05/17/2024 | VID1-005966-en-US A
Two-Stage Revision ACL Reconstruction
Two-Stage Revision ACL Reconstruction
Seth L. Sherman, MD
10:52 | English | 04/04/2024 | VID1-005892-en-US A
My “Alternative” Graft of Choice
My “Alternative” Graft of Choice
Walter R. Lowe, MD
06:07 | English | 11/23/2021 | VID1-002889-en-US A
ACL Reconstruction: What Is My Graft of Choice?
ACL Reconstruction: What Is My Graft of Choice?
Rachel M. Frank, MD
12:53 | English | 11/22/2021 | VID1-002890-en-US A
Improving Outcomes Through Biologic ACL Augmentation
Improving Outcomes Through Biologic ACL Augmentation
Chad Lavender, MD
09:59 | English | 11/22/2021 | VID1-002883-en-US A
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® Implant and FlipCutter® III Drill
QuadLink™ ACL Reconstruction Using FiberTag® TightRope® Implant and FlipCutter® III Drill
Jason M. Scopp, MD
02:54 | English | 09/09/2020 | VID1-000872-en-US C

Catalogs (1)

Knee Next Generation in Repair and Reconstruction
Knee Next Generation in Repair and Reconstruction
English | 11/05/2024 | LB1-0115-en-US AC

Event Clips (1)

QuadPro™ Tendon Harvester and FiberTag® TightRope® Implant
QuadPro™ Tendon Harvester and FiberTag® TightRope® Implant
01:00 | English | 09/21/2022 | evCLTL1-000339-en-US B

Presentation Videos (2)

ACL Quad Graft: Retrospective Review of 1300 Procedures
ACL Quad Graft: Retrospective Review of 1300 Procedures
John W. Xerogeanes, MD
08:47 | English | 10/21/2021 | VID1-002876-en-US A
Second Look: Bone Quad Tendon (BQT) QuadLink™
Second Look: Bone Quad Tendon (BQT) QuadLink™
Jason M. Scopp, MD
05:36 | English | 10/05/2018 | VPT1-01104-EN A

Product Demonstrations (2)

FiberTag® TightRope® II Implant With InternalBrace™ Technique Tips and Pearls
FiberTag® TightRope® II Implant With InternalBrace™ Technique Tips and Pearls
Justin Boyle
07:31 | English | 08/01/2023 | VID1-004022-en-US A

Scientific Updates (2)

InternalBrace™ Technique: Knee Applications
InternalBrace™ Technique: Knee Applications
English | 09/26/2024 | DOC1-000161-en-US I

SpeedPearls (2)

SpeedPearl: All-Inside ACL Reconstruction Using a Weighted Clamp
SpeedPearl: All-Inside ACL Reconstruction Using a Weighted Clamp
Peter C. Yeh, MD
00:59 | English | 12/10/2024 | VID1-006888-en-US A
SpeedPearl: Quad Tendon ACL Reconstruction - Initial Exposure and Dissection
SpeedPearl: Quad Tendon ACL Reconstruction - Initial Exposure and Dissection
Rachel M. Frank, MD
00:44 | English | 06/07/2024 | VID1-006216-en-US A

Surgeon Newsletters (2)

Scope This Out Volume 25 Number 2
Scope This Out Volume 25 Number 2
English | 08/16/2024 | LN1-000600-en-US A
Scope This Out - Volume 22, Number 2
Scope This Out - Volume 22, Number 2
English | 08/09/2021 | LN1-000351-en A

Tray Lists (1)

Minimally Invasive Quad Tendon Set (AR-2382S)
Minimally Invasive Quad Tendon Set (AR-2382S)
English | 03/27/2019 | DOC1-000036-en-US A

Video Series (4)

BreakThrough™ With Christopher Adams—Quad ACL Episode 1: Innovative Solutions
BreakThrough™ With Christopher Adams—Quad ACL Episode 1: Innovative Solutions
Christopher Adams, MD | John W. Xerogeanes, MD | J. Lee Pace, MD
05:34 | English | 04/05/2023 | VID1-003467-en-US A
BreakThrough™ With Christopher Adams—Quad ACL Episode 2: Technique Play-by-Play
BreakThrough™ With Christopher Adams—Quad ACL Episode 2: Technique Play-by-Play
Christopher Adams, MD | Frank A. Cordasco, MD, MS | Rachel M. Frank, MD
05:54 | English | 04/05/2023 | VID1-003468-en-US A
BreakThrough™ With Christopher Adams—Quad ACL Episode 3: Making the Case
BreakThrough™ With Christopher Adams—Quad ACL Episode 3: Making the Case
Christopher Adams, MD | Frank A. Cordasco, MD, MS | Rachel M. Frank, MD
09:09 | English | 04/05/2023 | VID1-003469-en-US A
BreakThrough™ With Christopher Adams—Quad ACL Episode 4: Lessons Learned
BreakThrough™ With Christopher Adams—Quad ACL Episode 4: Lessons Learned
Christopher Adams, MD | John W. Xerogeanes, MD | J. Lee Pace, MD
04:36 | English | 04/05/2023 | VID1-003470-en-US A

Customer ServiceLatex Information